With model A-10 of WIKA we have added a new generation of pressure transmitters for general industrial applications to our product range. The instrument is impressive not only due to its compact size, but also by its excellent quality and very competitive price.
- Product description
- Extra information
- Downloads
-
With model A-10 of WIKA we have added a new generation of pressure transmitters for general industrial applications to our product range. The instrument is impressive not only due to its compact size, but also by its excellent quality and very competitive price.There is choice of a non-linearity 0.25% or 0.5%. A test certificate is supplied.The A-10 pressure transmitter is suitable for worldwide use thanks to the international authorisations. All common pressure ranges and process connections are available.Features
• Measuring range: from 0...1 bar to 0... 600 bar
• Vacuum range: from-1 ... 9 bar to-1 ... 24 bar, kPa-range 0 ... 100 kPa to 0 ... 60,000 kPa
• Non-linearity: 0.25% or 0.5%
• Output signal: 4-20 mA/0-10 V/0-5 V/1-6 V/0.5-4 .5V ratiometric
• Electric connection: DIN 17531-803 A and C (L-connection), M12x1, Flying lead
• Pressure connection: G1/4 DIN 3852-E, 1/4NPT, oil and fat free
• Conditions: medium-30 ...85 ° c, environment-20 ... 80 ° f, vibrations 20 g -
Specifications Pressure rangesbar11.62,546101625Over pressure safetybar23.25812203250Burst pressurebar51010173434100100Pressure rangesbar4060100160250400600Over pressure safetybar801202003205008001200Burst pressurebar4005508001000120017002400MPa and kg/cm2 are available {Absolute pressure: 0 ... 1 bar up to 0 ... 25 bar}Pressure rangespsi15253050100160200300Over pressure safetypsi306060100200290400600Burst pressurepsi7515015025050050015001500Pressure rangespsi5001000150020003000500010000Over pressure safetypsi100017402900400060001000017400Burst pressurepsi250079751160014500174002465034800{Absolute pressure: 0 ... 15 psi up to 0 ... 300 psi}Vacuum resistanceAs of 0 ... 10 barFatigue life10 Mio. max. load cyclesMaterialsWetted parts» Pressure Connection316 L» Pressure sensor316 L (as of 0 ... 10 bar rel 13-8 PH)Internal transmission fluidSilicone oil (only with pressure ranges < 0 ... 10 bar and ≤ 0 ... 25 bar abs)Case316 LPower supply UBUB in VDC8 ... 30 {8 ... 36 1)}maximum ohmic load RA14 ... 30 {14 ... 36} with signal output 0 ... 10 V, 5 ± 10 % with signal output 0,5 ... 4,5 V ratiometric1) not with non-linearity 0.25 % BFSL and 4 ... 20 mASignal output andRA in Ohm4 ... 20 mA, 2-wireRA ≤ (UB – 8 V) / 0.02 Amaximum ohmic load RA0 ... 10 V, 3-wireRA > 10 k0 ... 5 V, 3-wireRA > 5 k1 ... 5 V, 3-wireRA > 5 k0.5 4.5 V, 3-wireRA > 4.5 k0.5 4.5 V, ratiometricRA > 4.5 k {other signal outputs on request}Setting timems< 4Current consumptionmASignal current (max. 25) for current output, Max. 8 for voltage output signalInsulation voltageVDC500 2)2) For power supply, use a circuit with energy limitation (EN/UL/IEC 61010-1, section 9.3) with the following maximum values for the current: bei UB = 30 V (DC): 5 A. Provide a separate switch for the external power supply. Alternative for North America: The connection may also be made to „Class 2 Circuits“ or „Class 2. Power Units“ according to CEC (Canadian Electrical Code) or NEC (National Electrical Code).Non-linearity% of span≤ ± 0.25(BFSL) according to IEC 61298-2≤ ± 0.5(BFSL) according to IEC 61298-2Adjusted in vertical mounting position with lower pressure connectionAccuracy 3)% of span≤ ± 0.5(with non-linearity 0.25 %)≤ ± 0.6 (with non-linearity 0.25 % and with signal output 0 ... 5 V)≤ ± 1.0(with non-linearity 0.5 %)3) Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement per IEC 61298-2)Zero offset% of span≤ 0.15 typ., ≤ 0.4 max.(with non-linearity 0.25 %)≤ 0.5 typ., ≤ 0.8 max.(with non-linearity 0.5 %)Hysteresis% of span≤ 0.16Non-repeatability% of span≤ 0.1Long-term drift% of span≤ 0.1according to IEC 61298-2Signal noise% of span≤ 0.3Permissible temperature ofMedium0 ... +80 °C {-30 ... +100 °C}+32 ... +176 °F {-22 ... +212 °F}Ambience0 ... +80 °C {-30 ... +100 °C}+32 ... +176 °F {-22 ... +212 °F}Storage-20 ... +80 °C {-30 ... +100 °C}-4 ... +176 °F {-22 ... +212 °F}Rated temperature range0 ... +80 °C+32 ... +176 °FTemperature error
within rated temperature range% of span≤ 1.0 typ., ≤ 2.5 max.ApprovalsUL, CSA, GOSTRoHS-conformityYesCE-conformityPressure equipment directive97/23/ECEMC directive89/336/EEC emission (class B) and immunity according to EN 61 326Shock resistanceg500 according to IEC 60068-2-27 (mechanical shock)Vibration resistanceg10 according to IEC 60068-2-6 (vibration under resonance) {20 g on request}Wiring protectionOvervoltage protectionVDC32; 36 with 4 ... 20 mAShort-circuit proofnessS+ towards UB-Reverse polarity protectionUB+ towards UB-Reference conditionsAccording to IEC 61298-1Relative humidity%45 ... 75WeightgApprox. 80 -
Documents:
Filename Upload date Size A-10 Series Datasheet 2019.9.25 0.36 MB