With advanced microprocessor technology and state-of-the-art silicon pressure sensors, Additel’s 161 and 161Ex series Digital Pressure Modules provide an accurate, reliable, and economic solution for wide range of pressure applications. Our intrinsically safe (Ex) models are up to the task of providing the best possible results, even in hazardous environments. In order to reach the best performance, every silicon pressure sensor in the module has been specially aged, tested and screened before assembly. Designed as external pressure modules for Additel’s 760 automatic handheld pressure calibrator, the ADT761 automated pressure calibrator, ADT226/ADT227 series handheld process calibrator and Additel’s flagship 780 pressure controller, the Additel 161 is unmatched in performance and reliability. If intrinsic safety is a critical requirement for your workload, we have you covered when you combine our model ADT226Ex/ADT227Ex process calibrator with any of our ADT161Ex pressure modules.
-
Differential Pressure
P/N
Pressure Range[1]
Media
Accuracy (%FS)
Burst Pressure
Static Pressure Range (inH2O)
(mbar)
DP1
±1
±2.5
G
0.05[2]
100×
±10 psi
DP2
±2
±5.0
G
0.05[2]
100×
±10 psi
DP5
±5
±10
G
0.05[2]
50×
±10 psi
DP10
±10
±25
G
0.05[2]
20×
±10 psi
DP20
±20
±50
G
0.05
20×
±10 psi
DP30
±30
±75
G
0.05
20×
±10 psi
DP50
±50
±160
G
0.05
3×
±10 psi
DP150
±150
±350
G
0.02 (0.05)
3×
50 psi
DP300
±300
±700
G
0.02 (0.05)
3×
50 psi
[1] FS specification applies to the span of the range. Accuracy includes one year stability. [2] 0.05%FS accuracy (incl 6 months stability). One year accuracy is 0.05%FS calibration accuracy combined with 0.05%FS one year stability.
Gauge Pressure[1]
P/N
Pressure Range
Media[2]
Accuracy (%FS)Burst Pressure psi
bar
V15
-15
-1
G
0.02
3×
GP2
2
0.16
G
0.05
3×
GP5
5
0.35
G
0.05
3×
GP10
10
0.7
G
0.02
3×
GP15
15
1
G, L
0.02
3×
GP30
30
2
G, L
0.02
3×
GP50
50
3.5
G, L
0.02
3×
GP100
100
7
G, L
0.02
3×
GP150
150
10
G, L
0.02
3×
GP300
300
20
G, L
0.02
3×
GP500
500
35
G, L
0.02
3×
GP600
600
40
G, L
0.02
3×
GP1K
1000
70
G, L
0.02
3×
GP2K
2000
140
G, L
0.02
3×
GP3K
3000
200
G, L
0.02
3×
GP5K
5000
350
G, L
0.02
3×
GP10K
10000
700
G, L
0.02
3×
GP15K
15000
1000
G, L
0.05
2×
GP20K
20000
1400
G, L
0.05
1.5×
GP25K
25000
1600
G, L
0.1
1.5×
GP30K
30000
2000
G, L
0.1
1.5×
GP36K
36000
2500
G, L
0.1
1.5×
GP40K
40000
2800
G, L
0.1
1.35×
GP50K
50000
3500
G, L
0.1
1.2×
GP60K
60000
4200
G, L
0.1
1.1×
[1] Sealed gauge pressure for above 1,000 psi [2] G=Gas, L=Liquid
Precision Sensors[1] - Absolute Pressure
P/N
Pressure Range
Media
Accuracy[2]
Pressure Rating
psia
bar.a
Burst
Over Pressure
AP15R
0 to 15
0 to 1
G
0.01% FS
2x
1.2x
AP30R
0 to 30
0 to 2
G
0.01% rdg or 0.003% FS whichever is greater
2x
1.2x
AP50R
0 to 50
0 to 3.5
G
0.01% rdg or 0.003% FS whichever is greater
2x
1.2x
AP100R
0 to 115
0 to 8
G,L
0.01% rdg or 0.003% FS whichever is greater
2x
1.2x
AP300R
0 to 315
0 to 21
G,L
0.01% rdg or 0.003% FS whichever is greater
2x
1.2x
AP500R
0 to 515
0 to 36
G,L
0.01% rdg or 0.003% FS whichever is greater
2x
1.2x
AP1KR
0 to 1,015
0 to 71
G,L
0.01% rdg or 0.003% FS whichever is greater
2x
1.2x
AP2KQ
0 to 2,015
0 to 141
G
0.005% rdg + 0.005% FS
3x
1.1x
AP3KQ
0 to 3,015
0 to 201
G
0.005% rdg + 0.005% FS
3x
1.1x
AP6KQ
0 to 6,000
0 to 400
G,L
0.01% FS
3x
1.2x
AP10KQ
0 to 10,000
0 to 700
G,L
0.01% FS
2x
1.2x
AP15KQ
0 to 15,000
0 to 1000
G,L
0.01% FS
2x
1.2x
AP20KQ
0 to 20,000
0 to 1400
G,L
0.01% FS
2x
1.2x
AP30KQ
0 to 30,000
0 to 2000
G,L
0.02% FS
1.5x
1.1x
AP40KQ
0 to 40,000
0 to 2800
G,L
0.02% FS
1.5x
1.1x
[1] Contact Additel for other range options. [2] Accuracy includes calibration uncertainty, linearity and long-term stability.
Compound Pressure
P/N
Pressure Range
Media
Accuracy
Pressure Rating
psig
bar.g
Burst
Over Pressure
CP2
±2
±0.16
G
0.05% FS
3x
1.2x
CP5
±5
±0.35
G
0.02% FS
3x
1.2x
CP10
±10
±0.7
G
0.02% FS
3x
1.2x
CP15
±15
±1.0
G
0.02% FS
3x
1.2x
CP30
-15 to 30
-1 to 2.0
G
0.02% FS
3x
1.2x
CP50
-15 to 50
-1 to 3.5
G
0.02% FS
3x
1.2x
CP100
-15 to 100
-1 to 7.0
G,L
0.02% FS
3x
1.2x
CP300
-15 to 300
-1 to 20
G,L
0.02% FS
3x
1.2x
CP500
-15 to 500
-1 to 35
G,L
0.02% FS
3x
1.2x
CP600
-15 to 600
-1 to 40
G,L
0.02% FS
3x
1.2x
CP1K
-15 to 1,000
-1 to 70
G,L
0.02% FS
3x
1.2x
CP2K
-15 to 2,000
-1 to 140
G,L
0.02% FS
3x
1.2x
CP3K
-15 to 3,000
-1 to 200
G,L
0.02% FS
3x
1.2x
CP5K
-15 to 5,000
-1 to 350
G,L
0.02% FS
3x
1.2x
CP10K
-15 to 10,000
-1 to 700
G,L
0.02% FS
2x
1.2x
Absolute Pressure
P/N
Pressure Range
Media
Accuracy (%FS)
Burst Pressure
psi
bar
AP5
5
0.35
G
0.1
3×
AP10
10
0.7
G
0.1
3×
AP15
15
1
G
0.1
3×
AP30
30
2
G
0.1
3×
AP50
50
3.5
G
0.1
3×
AP100
100
7
G , L
0.05 (0.1)
3×
AP300
300
20
G , L
0.05 (0.1)
3×
AP500
500
35
G , L
0.05 (0.1)
3×
AP1K
1000
70
G , L
0.05 (0.1)
3×
AP3K
3000
200
G , L
0.05 (0.1)
3×
AP5K
5000
350
G , L
0.05 (0.1)
3×
Barometric Pressure
P/N
Pressure Range
Media
Accuracy
Burst Pressure
Low
High
BP
60 kPa
110 kPa
G
40 Pa
3×
Additel 226Ex with ADT161Ex Pressure Module Standard Accuracy Precision Accuracy CPXXX DPXXX GPXXX APXXQ APXXR Operating temperature -10°C to 50°C (14°F to 122°F) 15°C to 25°C (59°F to 77°F) 10°C to 30°C (50°F to 86°F) Storage temperature -20°C to 70°C (-4°F to 158°F) -20°C to 70°C (-4°F to 158°F) Relative humidity 95% RH 90% RH Pressure connections (for external use only) 1/4NPT, 1/2NPT, 1/4BSP, 1/2BPS, M20x15 1/4NPT, 1/2NPT, 1/4BSP, 1/2BSP, M20x15 Enclosure (for external use only) SS enclosure SS enclosure Intrinisic Safety (ADT161Ex models only) ATEX certified intrinsically safe II 1G EX ia IIC T4 Ga TUR 16.0023X N/A Dimensions (Dia x H) 33 mm x 123 mm (1.3” x 4.84”) Depends on the model 44 mm x 195 mm (1.7” x7.7”) Weight 0.4 kg (0.99 lb) Depends on the model 0.7 kg (1.5 lb) Warranty 1 Year 1 Year 1 Year -
Documents: