Additel 878 Reference Dry Well Calibrators
Price on request
We are taking temperature calibration to the next level with the Additel 878 Reference Dry Well Calibrators.
- Product description
- Extra information
- Video
- Downloads
-
We are taking temperature calibration to the next level with the Additel 878 Reference Dry Well Calibrators.
Additel introduces their new ADT878 Reference Dry Well Calibrator series which consist of three products that combine to cover a temperature range from –40°C to 700°C. The Additel Reference Dry Wells are designed with laboratory-level performance in accuracy, stability, uniformity, loading and hysteresis and combine automation features to automatically realize and maintain a triple point of water cell and facilitate annealing PRTs. Each unit has a process calibration option which includes a full HART communicator, measurement of a reference PRT and two devices under test that can measure mA, V, switch, RTD or thermocouple. In addition to these functions, this calibrator can create and store tasks and document the “as found” and “as left” results.There are three ranges to choose from: low temperature –40C° to 160°C (ADT878-160), mid-temperature 33°C to 425°C (ADT878-425), and high temperature 33°C to 700°C (ADT878-700). Each unit has performance specifications related to the guidelines published in Euramet cg-13 specifying stability, radial and axial uniformity, loading, and hysteresis.
We are certain that you will be blown away by the outstanding performance of these game-changing Reference Dry Wells!
- Three models ranging from -40℃ to 700℃
- Reference level performance in accuracy, stability and uniformity
- Quick to temperature
- Two-channel readout measures RTDs and TCs, and provides task
- Documentation
- Full HART communicator
- Optional external temperature control
- Wi-Fi and Bluetooth capable
- Color touch screen display
- Easy push quick connectors
- Set point control by reference
- Self-calibration feature
- Optional TPW kit for built-in automatic realization (ADT878-160 only)
- Build-in automatic annealing feature (ADT878-700 only)
-
Reference Dry Well Specifications
Specification878-160878-425878-700Temperature Range at 23°C-40°C to 160°C33°C to 425°C33°C to 700°CDisplay Accuracy±0.1°C at Full Range±0.2°C at Full Range±0.20°C at 33°C±0.20°C at 425°C±0.25°C at 660°CStability (30 min)±0.005°C at Full Range±0.005°C at 100°C±0.005°C at 100°C±0.010°C at 225°C±0.015°C at 425°C±0.015°C at 425°C±0.030°C at 700°CAxial Uniformity at 60 mm (2.4 in)±0.025°C at -40°C±0.10°C at 100°C±0.10°C at 100°C±0.020°C at 0°C±0.15°C at 225°C±0.25°C at 425°C±0.050°C at 160°C±0.25°C at 425°C±0.40°C at 700°CAxial Uniformity at 80 mm (3.15 in)±0.050°C at -40°C±0.15°C at 100°C±0.15°C at 100°C±0.040°C at 0°C±0.20°C at 225°C±0.30°C at 425°C±0.050°C at 160°C±0.30°C at 425°C±0.60°C at 700°CRadial Uniformity±0.01°C at Full Range±0.025°C at 100°C±0.025°C at 100°C±0.030°C at 225°C±0.040°C at 425°C±0.040°C at 425°C±0.060°C at 700°CLading Effect±0.08°C (Display Sensor)±0.05°C (Display Sensor)±0.02°C at 100°C±0.05°C at 425°C±0.15°C at 700°C±0.010°C (External Sensor)±0.01°C (External Sensor)±0.01°C at 100°C±0.02°C at 425°C±0.03°C at 700°CHysteresis (Display Sensor)0.025°C0.04°C0.07°CEnvironmental Conditions8°C to 38°C guaranteed accuracy0°C to 50°C, 0% to 90% RH non-condensingStorage Conditions-20°C to 60°CIP RatingIP20Immersion Depth160 mm (1.30 in)193 mm (7.60 in)Insert OD31.9 mm (1.26 in)30.8 mm (1.21 in)Heating Time4 min: -40°C to 23°C15 min: 23°C to 425°C25 min: 23°C to 700°C10 min: 23°C to 160°CCooling Time8 min: 160°C to 23°C24 min: 425°C to 100°C30 min: 700°C to 100°C15 min: 23°C to -40°C15 min: 100°C to 50°C15 min: 100°C to 50°CTypical Time to Stability10 minResolution 0.001°CUnits°C, °F, and KDisplay6.5 in (165 mm) color touch screenSize (H x W x D)170 x 345 x 330 mm (6.69 x 13.58 x 13.0 in)Weight11.2 kg (24.7 lbs)9.7 kg (21.4 lbs)Power Requirements90-254 VAC, 45-65 Hz, 580 W90-254 VAC, 45-65 Hz, 1400 WCommunicationUSB A, USB B, RJ45, WiFi, BluetoothLocalizationEnglish, Chinese, Japanese, Russian, German, French, Italian, and SpanishWarranty1 year
Input Specifications (Process Calibrator [PC] Option)SpecificationDescriptionReadout Accuracy for 100 ohm PRT (Probe Accuracy Not Included)±0.006°C at 0°C±0.008°C at 50°C±0.009°C at 100°C±0.011°C at 160°C±0.015°C at 300°C±0.019°C at 425°C±0.026°C at 660°C±0.028°C at 700°CReadout Resolution0.1 mΩReference Resistance Range-200Ω to 926ΩReference Resistance Accuracy0Ω to 50Ω: ±1.25mΩ50Ω to 400Ω: ±0.0025% RDReference CharacterizationsITS-90, CVD, IEC-751Reference Measurement Capability4-wire PRTReference Probe Connection6-pin lemo smart connector and Quick-Push connectors to accept banana, mini-banana, large & small spade lug and bare wire connectionsRTD Channels2RTD Measurement Accuracy (excl sensor) Compliance0Ω to 50Ω: ±2.5mΩ50Ω to 4000Ω: ±0.005% RDRTD Measurement Resolution0.1mΩRTD Measurement Resistance Range0Ω to 4KΩRTD CharacterizationsPT10, PT25, PT50, PT100, PT200, PT500, PT1000, CU10, CU50, CU100, NI100, NI120RTD ConnectionQuick-Push connectors accept banana, mini-banana, large & small spade lug and bare wire connectionsRTD Channels2 channels. Both accept 2, 3, or 4-wire RTDsTC Channel2TC Measurement ChannelsAccepting S, R, K, B, N, E, J, T, C, D, G, L,and UTC Range–75 mV to 75 mVTC Resolution0.1µVTC Voltage Accuracy0.01% RD + 5 µVInternal CJC Accuracy±0.2°C (ambient from 0°C to 50°C)Current Range–30 mA to 30 mACurrent Accuracy0.01% RD + 2 µACurrent Resolution0.1 µA, Input Impedance: < 10ΩSpecificationDescriptionVoltage Range–30 V to 30 VVoltage Accuracy±0.01% RD + 0.6 mVVoltage Resolution0.1 mV; Input impedance: >1MΩSwitch TestMechanical or ElectricalDC 24V Output24 V ±0.5 V, MAX 60 mAHart CommunicatorRead, configure and calibrate HART devices- DD files updated periodically Optional - (order ADT875PC)DocumentationUp to 1,000 tasks which store up to 10 results each containing as found and as left data. Snap shot feature allows for screen captures. Records auto step and ramp functions.Temperature Coefficient 0℃ to 13℃ and 33℃ to 50℃ADT878 (PC)-160: ±0.005°C/°CADT878 (PC)-425/700: ±0.005°C/°CRef Readout: ±1 ppm FS/°CRTD Readouts: ±1 ppm FS/°CTC Readouts: ±5 ppm FS/°CCurrent: ±5 ppm FS/°CVoltage: ±5 ppm FS/°C
TC Measurement Specification and Calculation
(Process Calibrator [PC] Option)TC TypeTemperature (°C) Error (°C)[1]TC TypeTemperature (°C)Error (°C)[1]B250±1.99T-200±0.28300±1.65-40±0.14425±1.180±0.13660±0.81160±0.11700±0.77300±0.111768±0.56400±0.11K-200±0.29N-200±0.46-40±0.13-40±0.200±0.130±0.19160±0.14160±0.17300±0.15300±0.17425±0.16425±0.17660±0.18660±0.19700±0.19700±0.191000±0.311000±0.27E-200±0.16S-50±1.25-40±0.09-40±1.170±0.090±0.93160±0.08160±0.63300±0.09300±0.57425±0.10425±0.55660±0.12660±0.54700±0.13700±0.531000±0.171768±0.66J-210±0.22R-50±1.33-40±0.10-40±1.230±0.100±0.95160±0.11160±0.61300±0.12300±0.54425±0.13425±0.51660±0.14660±0.48700±0.14700±0.481000±0.211768±0.58
[1] Excluding cold junction compensation errors. -
Documents:
Filename Upload date Size Additel 878 Reference Dryblock Calibrator Datasheet 2020.9.17 2.9 MB Additel 878 Reference Dryblock Calibrator User Manual 2021.2.2 1.6 MB Additel Short Probe Temperature Calibration Kit Datasheet 2019.6.19 0.6 MB Additel 878-TPW-KIT Triple Point of Water Realization Kit Datasheet 2020.9.22 0.7 MB Additel Hart Communication Manual 2020.7.28 0.4 MB
Update Packages:Filename Upload date Size Additel 875 Firmware Update Package 2021.1.13 14.6 MB