Easidew I.S. Dew-Point Transmitter
Price on request
The Easidew I.S. (intrinsically safe) transmitter is a dew-point transmitter designed and certified for use in hazardous area applications (flammable or explosive gases) in all regions with certification from: IECEx, CSA, FM and ATEX.
- Product description
- Extra information
- Downloads
-
The Easidew I.S. (intrinsically safe) transmitter is a dew-point transmitter designed and certified for use in hazardous area applications (flammable or explosive gases) in all regions with certification from: IECEx, CSA, FM and ATEX.
The Easidew I.S. is available with a a 5/8" UNF process connection or alternatively with a G1/2" BSP or 3/4" UNF process connection. It is designed for ease of use, incorporating all of the features needed to make installation and operation into your air or gas management system as simple as possible.
Michell's Advanced Ceramic Moisture Sensor technology based transmitter is calibrated to international standards and is delivered with a traceable calibration certificate. -
Easidew, Easidew M12 and Easidew 34 Transmitter
Easidew I.S. Transmitter
Performance Specifications
Measurement range
–110 to +20°C dew point; –100 to +20°C dew point; non standard ranges available on request
Accuracy
±2°C dew point*
Response time
5 mins to T95 (dry to wet)
Repeatability
0.5°C dew point
Calibration
Traceable 13 point calibration certificate
Electrical Specifications
Output signal
4–20 mA (2-wire connection, current source); User configurable over range
Easidew M12: Modbus RTU over RS485Output
Dew point or moisture content
Analog output scaled range
Dew point: –110 up to +20°C; Moisture content in gas: 0– up to 3000 ppmV;
Supply voltage
12 to 28 V DC
Load resistance
Max 250 Ω @ 14 V (500 Ω @ 24 V)
Current consumption
23 mA max, depending on output signal
CE conformity
Approved
UL61010-1 & CAN/CSA C22.2 No. 61010-1
Operating Specifications
Operating temperature
-40 to +60°C
Compensated temperature range
-20 to +50°C
Storage Temperature
-40 to +60°C
Operating pressure
45 MPa (450 barg) maximum
Flow rate
1 to 5 Nl/min mounted in standard sampling block; 0 to 10 m/sec direct insertion
Mechanical Specifications
Ingress protection
IP66 in accordance with standard BS EN 60529:1992; NEMA 4 protection in accordance with standard NEMA 250–2003
Easidew M12: IP65Intrinsically safe area certificates
ATEX: II 1 G Ex ia IIC T4 Ga (-20 to +70 °C) IECEx: EX ia IIC T4 Ga (-20 to +70 °C) TC TR@ 0Ex ia IICT4 Ga (-20 to +70 °C) FM: Class I, Division 1, Groups A B C D, T4 CCSAUS: Class I, Division 1, Groups A B C D, T4
Oxygen service
Optional: cleaned for enriched oxygen
Housing material
316 stainless steel
Dimensions
MiniDIN 43650 form C L=132mm x ø45mm (with connector cable)
Easidew M12: M12 5 pin L = 155mm x ø45mm (with connector cable)Filter (sensor protection)
Standard: HDPE <10μm
Optional: 316 stainless steel sintered guard <80μmProcess connection
Easidew: 5/8” - 18 UNF
Easidew 34: 3/4” - 16 UNF
Easidew M12: 5/8” -18 UNF, 3/4” - 16 UNF, G1/2” BSP5/8” -18 UNF, 3/4” - 16 UNF, G1/2” BSP
Weight
150g
Electrical connections
Easidew: MiniDIN 43650 form C
Easidew M12: M12 5 Pin (A coded)MiniDIN 43650 form C
Mating Electrical Connectors
Mating connector supplied as standard
Easidew M12: optional 0.8, 2, 5 metre M12 A coded connector/cable availableDiagnostic conditions (factory programmed)
Conditions
Sensor fault
Under-range dew point
Over-range dew point
Output
23 mA
4 mA
20 mAApproved galvanic isolators
KFD2-CR-EX1.20200
KFD2-CR-EX1.30200
KFD0-CS-EX1.50P
KFD0-CS-EX2.50P
KFD2-STC4-EX1.H
MTL5041
MTL5040NOTES * Over Compensated Temperature Range
-
Documents:
File name Upload Date Size Datasheet Easidew I.S. 2019.5.28 0.1 MB