- Product description
- Extra information
- Downloads
-
The pyrometer optris CSmicro LT LTH is equipped with an innovative, miniaturized stainless steel measuring head, optimally suited for installation in limited spaces. Its small size and its temperature resistance up to 180°C make the mechanic integration of the measuring head especially cost-efficient.
The intelligent LED display works optionally as alarm signal, target support, self-diagnosis or temperature-code display. The placement of electronic components within the cable allows for a high temperature resistance of the measuring head.
New: The CSmicro series can now be operated
via the new IR mobile App (Android). The App
enables to monitor and analyze infrared
temperature measurements on a connected
smartphone or tablet.Important specifications
- Temperature range: -50 to 1,030°C
- Spectral range: 8 to 14 µm
- Response time: 14 ms (LT) / 150 ms (LTH)
- NEW: IR mobile App
-
General Specifications
Environmental rating
IP 65 (NEMA-4)
Ambient temperature1)
–20 °C ... 180 °C (130°C to LT02) (sensing head)
–20 °C ... 85 °C (electronics)Storage temperature
–40 °C ... 130 °C (sensing head)
–40 °C ... 85 °C (electronics)Relative humidity
10 – 95 %, non condensing
Vibration (sensor)
IEC 68-2-6: 3 G, 11 – 200 Hz, any axis
Shock (sensor)
IEC 68-2-27: 50 G, 11 ms, any axis
Weight
40 g (sensing head) / 420 g (electronics)
Electrical Specifications
Outputs / analog
Channel 1:0/4 – 20 mA, 0 – 5/ 10 V, thermocouple J, K Channel 2: sensind head temperature (–20 °C ... 180 °C as 0 – 5 V or 0 – 10 V), alarm output
Output / alarm
24 V / 50 mA (open collector)
Optional
Relay: 2 x 60 V DC/ 42 V ACeff; 0.4 A; optically isolated
Outputs / digital
USB, RS232, RS485, CAN, Profibus DP, Ethernet (optional)
Output impedances
mA max. 500 Ω (with 8 – 36 V DC) mV min. 100 kΩ load impedance thermocouple 20 Ω
Inputs
Programmable functional inputs for external emissivity adjustment, ambient temperature compensation, trigger (reset of hold functions)
Cable length
1 m (standard), 3 m, 8 m, 15 m
Power Supply
8 – 36 V DC
Current draw
Max. 100 mA
Measurement specifications
Temperature range (scalable via programming keys or software)
–50 °C ... 975 °C (LT22)
–50 °C ... 600 °C (LT15)
–50 °C ... 600 °C (LT02)
–50 °C ... 600 °C (LT02)Spectral range
8 – 14 μm
Optical resolution (90 % energy)
22:1 (precision glass optics)
15:1 (precision glass optics)
2:1 (with flat front window)CF-lens (optional)
0.6 mm @ 10 mm (with LT22)
0.8 mm @ 10 mm (with LT15)
2.5 mm @ 23 mm (with LT02)System accuracy 2),3)
(at ambient temp. 23 ±5 °C)±1 % or ±1 °C
Repeatability2),3)
(at ambient temp. 23 ±5 °C)±0.5 % or ±0.5 °C
Temperature resolution (display)
0.1 K
NETD3), 4)
0.05 K (LT22 / LT15)
0.1 K (LT02)Response time
150 ms (95 %)
Emissivity/ Gain
(adjustable via programming keys or software)0.100 – 1.100
Transmissivity/ Gain (adjustable via programming keys or software)0.100 – 1.100 Signal processing (parameter adjustable via programming keys or software, respectively)
Peak hold, valley hold, average; extended hold function with threshold and hysteresis
Software
optris® Compact Connect
1) The LCD displays capacity may be limited at ambient temperatures below 0 °C.
2) Whichever is greater
3) At object temperatures >0 °C, ε = 1
4) At time constant 200 ms and TObj 25 °C -
Documents:
Filename Upload date Size Optris CT LT Datasheet 2019.3.25 0.53 MB Optris CT-EX LT Datasheet 2019.3.25 0.60 MB Optris CT LT Manual 2019.3.11 4.4 MB