PACE 6000
Fasted pressure controller on the market
Price on request
The PACE Series pneumatic pressure controller brings together the latest control and measurement technology to offer an elegant and economical solution to pressure control for production, test and calibration. It employs full digital control to provide high control stability and high slew rate, while its digitally characterized pressure sensor offers the quality, stability, higher bandwidth and precision associated with this latest generation of piezo-resistive devices.
- Product description
- Extra information
- Video
- Downloads
-
The PACE Series pneumatic pressure controller brings together the latest control and measurement technology to offer an elegant and economical solution to pressure control for production, test and calibration. It employs full digital control to provide high control stability and high slew rate, while its digitally characterized pressure sensor offers the quality, stability, higher bandwidth and precision associated with this latest generation of piezo-resistive devices.
With PACE CM3, we present a new custom-built system where the fastest pressure controller, PACE, and the most accurate reference control module, CM3, are combined into one powerful, high-precision pressure measurement and control solution.
Due to the inclusion of Druck established TERPS® (Trench Etched Resonant Pressure Sensor) technology at its core, CM3 delivers unprecedented metrological characteristics and resultant levels of performance for our controllers. TERPS® is a resonant silicon pressure sensor technology platform that combines accuracy, stability, reliability, and strength unmatched by comparable pressure sensors. TERPS® reduces the amount of time needed to calibrate a sensor, while a robust construction with hard media isolation protects data quality and laboratory-level accuracy–even in the toughest environments.Features
- Color touchscreen with high resolution
- To 210 bar (3000 psi/21 MPa) gauge and absolute
- Removable pressure plug and play modules
- Compatible with 4Sight2l and third party software
- USB, RS232 & IEEE communication system
- Negative calibration as a standard adjustment
- 24 units of measurements and four more to define by user
- Applies Druck's unique piezo-resistive and the new TERPS® sensor technology
- Performances both in 482 mm (19 inch) rack fitted as in a table model
Applications
Automatic testing and calibrating pressure recorders, pressure indicators, pressure switches and pressure transmitters.
The PACE 5000 and the PACE 6000 are suitable for:- Instrument workshops
- Service companies
- Automotive test cells
- Manufacturing
- Burst tests
-
Pressure Measurement
CM0/CM1/CM2 Pressure Ranges:
25, 70, 200, 350 and 700 mbar gauge, 1, 2, 3.5, 7, 10, 20, 35, 70, 100, 135, 172, 210 bar gauge
0.35, 1, 3, 5, 10, 15, 30, 50, 100, 150, 300, 500, 1000, 1500, 2000, 2500, 3000 psi gauge
2.5, 7, 20, 35, 70, 100, 200, 350, 700 kPa gauge, 1, 2, 3.5, 7, 10, 13.5, 17.2, 21 MPa gauge
All gauge versions available with negative calibration as standard. For absolute pressure ranges select any range of 1 bar and above and add barometric optionCM3 Pressure Ranges: 2, 3.5 bar absolute; 30, 50 psi absolute; 200, 350 kPa absolute 7,10,20,35 and 70 bar pseudo Gauge
8, 11, 21, 36, 71 Bar a
100 (101), 150 (145), 300(290), 500 (507), 1000 (1015) Psi Gauge 116, 160, 304, 522, 1029 psi a
0.7, 1,2, 3.5, 7 MPa Gauge
0.8, 1.1, 2.1, 3.6, 7.1 MPa AbsOver Range Indication:
10% above mbar/bar full scale pressure range
Pressure Media:
Dry, oil free, non-corrosive gas maintained at a value of 10% above the maximum required outlet pressure, Dry air or Nitrogen recommended.
Display
PACE5000
4.3” TFT colour VGA resolution wide format display with integral touchscreen
PACE6000
7” TFT colour VGA resolution wide format display with integral touchscreen
Comms Update Rate
8 times per second
Display Update Rate
2 times per second
Readout
±9999999
Pressure Units
mbar, bar, Pa(N/m2), hPa, kPa, MPa, mmHg @ 0°C, cmHg @ 0°C, mHg @ 0°C,, inHg @ 0°C, mmH2O @ 4°C, cmH2O @ 4°C, mH2O @ 4°C, mmH2O @ 20°C, cmH2O @20 °C, mH2O @ 20 °C, kg/m2, kg/cm2, torr, atm, psi, lb/ft2, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F, User Defined 1, User Defined 2, User Defined 3, User Defined 4
Performance
PACE CM0 Standard Precision
0.02% Rdg + 0.02% FS (25 mbar: 0.20% rdg + 0.20% FS, 70 mbar: 0.10% rdg + 0.10% FS, 200 mbar: 0.04% rdg + 0.04% FS) includes linearity, hysteresis, repeatability and temperature effects over calibrated temperature range, for gauge pressures and assumes steady state temperature and regular zeroing
PACE CM0 Controller Stability
0.005% FS
PACE CM1 High Precision
0.01% Rdg + 0.01% FS (25 mbar: 0.10% rdg + 0.10% FS, 70 mbar: 0.05% rdg + 0.05% FS, 200 mbar: 0.02% rdg + 0.02% FS) includes linearity, hysteresis, repeatability and temperature effects over calibrated temperature range, for gauge pressures and assumes steady state temperature and regular zeroing
PACE CM1 Controller Stability
0.003% FS (25mbar range = 0.005% FS)
PACE CM2 Premium Precision
0.005% Rdg + 0.005% FS (25 mbar: 0.05% rdg + 0.05% FS, 70 mbar: 0.025% rdg + 0.025% FS, 200 mbar: 0.01% rdg + 0.01% FS) includes linearity, hysteresis, repeatability and temperature effects over calibrated temperature range, for gauge pressures and assumes steady state temperature and regular zeroing
PACE CM2 – Controller Stability
0.001% FS (25mbar = 0.004% FS. 70 mbar = 0.003% FS)
PACE CM2-A Aeronautical
Altitude range: -3000 to +55,000 ft
Altitude precision: @ Sea level ±2 ft, @ 8500 ft ±3 ft, @ 35,000 ft ±9 ft
Altitude RVSM accuracy: @ Sea level ±5 ft, @ 29,000 ft ±25 ft, @ 41,000 ft ±46 ft, @ 35,000 ft ±33 ft
Airspeed range: to 650 knots
Airspeed precision: @ 50 knots ±1.00 kts, @ 250 knots ±0.21 kts, @500 knots ±0.11 kts
Pressure Range –1 to +1bar g, pressure precision 0.005% Rdg + 0.005% FS includes linearity, hysteresis, repeatability and temperature effects for gauge pressures and assumes steady state temperature and regular zeroing.
1300 mbar reference precision 0.005% FS, Includes non-linearity, hysteresis, repeatability and temperature effects over calibrated temperature range.PACE CM3 Reference Precision
0.001% FS for 2, 3.5 bar a includes non-linearity, hysteresis, repeatabilty and temperature effects over calibrated temperature range
0.0015% FS for 8-71 bar a includes non-linearity, hysteresis, repeatabilty and temperature effects over calibrated temperature rangePACE CM3 Controller Stability
0.001% of absolute range FS
PACE CM3 Accuracy
Absolute ranges 2, 3.5 bar accuracy (2 Sigma) over calibrated temperature range 0.0016%Rdg + 0.0033% FS. 8-71 bar 0.0011% RDG + 0.0026 % FS*.
Includes measurement precision, measurement long term stability (see below) and calibration equipment expanded uncertainty. Pseudo gauge ranges accuracy will need to include the barometer uncertainty using the RSS (root sum of squares) method.PACE CM Measurement Long Term Stability
CM0, CM1 and CM2 Ranges: 2 bar g to 210 bar g (30 psi g to 3000 psi g) 0.01% of reading per annum, 1 bar g 0.02% of reading per annum and 25 mbar g to 700 mbar g 0.03% of reading per annum, assumes regular Zeroing
CM3 Ranges: 2, 3.5 bar a 0.0025% FS per annum absolute ranges. CM3 Ranges: 8-71 bar a 0.001% FS per 28 days*
CM0-B, CM1-B, CM2-B, CM3-B and CM2-A: Barometric reference sensor 0.05 mbar a or 0.00072515 psi a per annum.Performance (cont.)
Negative Gauge Precision
Maximum error at any given pressure value is equal to maximum error at the equivalent positive pressure value (CM0, CM1 and CM2).
Pseudo Range Precision
Pseudo Absolute: gauge mode precision + barometric reference precision
Pseudo Gauge: absolute precision + barometric precisionPACE CM0-B Precision- Barometric Reference
Precision for the optional barometric reference 0.10 mbar or 0.001450 psi. Includes non-linearity, hysteresis, repeatability and temperature effects over calibrated temperature range.
PACE CM1-B Precision- Barometric Reference
Precision for the optional barometric reference 0.05 mbar or 0.000725 psi. Includes non-linearity, hysteresis, repeatability and temperature effects over calibrated temperature range.
PACE CM2-B Precision- Barometric Reference
Precision for the optional barometric reference 0.025 mbar or 0.0003625 psi. Includes non-linearity, hysteresis, repeatability and temperature effects over calibrated temperature range.
PACE CM3-B Precision- Barometric Reference
Precision for the optional barometric reference 0.020 mbar or 0.0002901 psi. Includes non- linearity, hysteresis, repeatability and temperature effects over calibrated temperature range.
PACE CM3-B Accuracy- Barometric Reference
Barometer accuracy (2 Sigma) = 0.1 mbar over the calibrated temperature range. Includes measurement precision, measurement long term stability per annum and calibration equipment expanded uncertainty ≤ (0.0032% Rdg + 0.7 Pa).
Gas Consumption
All supply gas is delivered to the system. No gas is used in measure mode, or when the instrument is turned off.
Electrical
Power Supply
90 V AC to 130 V AC @ 47 to 63 Hz & 180 V AC to 260 V AC @ 47 to 63 Hz. Universal input via IEC320 C14 Connector.
VFC Contact rating
30V d.c. 1 Amp resistive/200 mA inductive
Communications
Communication
RS232, USB and IEEE-488, SCPI, emulation (DPI520, DPI500, DPI510 & DPI515 depending on model) Ethernet (VXI-II & Sockets using SCPI)
Environmetal
Temperature
Operating 10°C to 50°C (50°F to 122°F) Calibrated 15°C to 45°C (59°F to 113°F) Storage -20°C to 70°C (-4°F to 158°F)
Humidity Sealing Vibration Shock Conformity
5% RH to 95% RH non-condensing IP20 (EN60529), In door use only
Compliant with Def. Stan. 66-31 8.4 Cat 3 and MIL-T-28800E Cat 2 Mechanical shock conforms to EN61010 LVD EN61010, EMC EN61326, PED, ROHS & WEEE - CE markedPhysical
PACE Chassis - Weight
PACE5000 5 Kg or 11 lbs, PACE6000 6.7 Kg or 17.7 lbs
PACE CM – Weight
5 Kg or 11 lbs
PACE CM – Pressure Connection
G 1/8 Female (1/8 NPT Female by adaptor for North America)
PACE 5000 – Dimensions
440 mm X 88 mm (2U) X 320 mm (17.3” X 3.47” X 12.6”)
PACE 6000 – Dimensions
440 mm X 132 mm (3U) X 320 mm (17.3” X 5.2” X 12.6”)
*to achieve optimum performance zeroing against the internal barometer is recommended every 28 days
-
Documents:
Filename Upload date Size PACE 5000 / 6000 Series Datasheet 2019.3.25 5.3 MB PACE 5000 / 6000 Series Manual 2019.3.11 4.4 MB PACE 5000 / 6000 Firmware Update Information 2018.3.27 0.3 MB
Update Packages:Filename Upload date Size 2018.3.25 5.8 MB