PM 620
Price on request
The PM 620 printing module is the latest development in digital sensor technology with a number of important innovations. With the PM 620 you can vary between measuring ranges with compatible equipment, the DPI 620 series. A simple screw sensor enables a pressure and electrical connection with your DPI 620 without the need for tools, sealing tape, cables or plugs.
Anderen kochten ook:
- Product description
- Extra information
- Video
- Downloads
-
The PM 620 printing module is the latest development in digital sensor technology with a number of important innovations. With the PM 620 you can vary between measuring ranges with compatible equipment, the DPI 620 series. A simple screw sensor enables a pressure and electrical connection with your DPI 620 without the need for tools, sealing tape, cables or plugs. Thanks to the digital characterization of the sensor, you can easily exchange it without set-up or calibration. The modules are automatically recognized by your DPI 620 and in a few seconds your instrument is changed from pressure range.
The pressure modules can be used in combination with a pneumatic or hydraulic pressure station, the PV621, PV622 and PV623
In addition, there is a pressure module holder, the MC620, in which two pressure modules can be placed simultaneously.
The measuring ranges are available from 25 mbar to 1000 bar. See Extra description for specifications! -
General Specifications
Maximum Intermittent Pressure
2 x FS
Maximum Working Pressure
110% FS
Sealing
IP 65 (Protected against dust and jets of water)
Operating Temperature
-10° - 50°C (14° - 122°F)
Storage temperature
-20° - 70°C (-4° - 158°F)
Humidity
0 - 90% without Condensation
(Def stan 66-31, 8.6 cat III)Shock and Vibration
BS EN 61010:2001; Def stan 66-31, 8.4 cat III)
EMC
BS EN 61326-1:2006
Electrical Safety
BS EN 61010:2001
Pressure Safety
Pressure equipment Directive Class
Approval
CE marked
Size and Weight
100mm x 65mm 48mm, 100g
Specifications
Gauge Ranges (referenced - atmosphere)
Model
Bar
Psi
Compatible
Media typesNLH&R
20 ±2°C (68 ± 4°F)NLH&R
0 ± 50°C (32 ± 122°F)For 24 hrs
(%FS)For 24 hrs
(%FS)For 1 Year
(%FS)PM620-008G
±0.025
±10 inH2O
Non-corrosive gas/fluid
0.090
0.090
0.100
PM620-01G
±0.07
±1
0.025
0.030
0.047
PM620-02G
±0.2
±3
0.020
0.025
0.044
PM620-03G
±0.35
±5
Stainless Steel
0.020
0.025
0.044
PM620-04G
±0.7
±10
0.015
0.020
0.041
PM620-05G
±1
-14.5 to 15
0.015
0.020
0.041
PM620-07G
-1 to 2
-14.5 to 30
0.015
0.020
0.025
PM620-08G
-1 to 3.5
-14.5 to 50
0.010
0.020
0.025
PM620-10G
-1 to 7
-14.5 to 100
0.010
0.020
0.025
PM620-11G
-1 to 10
-14.5 to 150
0.005
0.020
0.025
PM620-13G
-1 to 20
-14.5 to 300
0.005
0.020
0.025
PM620-14G
0 to 35
0 to 500
0.005
0.020
0.025
PM620-16G
0 to 70
0 to 1000
0.005
0.020
0.025
PM620-165G
0 to 100
0 to 1500
0.005
0.020
0.025
PM620-17G
0 to 135
0 to 2000
0.005
0.020
0.025
PM620-18G
0 to 200
0 to 3000
0.005
0.020
0.025
Absolute Ranges (referenced - Vacuum)
Model
Bar
Psi
Compatible
Media typesNLH&R
20 ±2°C (68 ± 4°F)NLH&R
0 ± 50°C (32 ± 122°F)For 24 hrs
for 24 hrs
for 1 Year
Absolute Gauge
(%FS)Sealed Gauge
(%FS)Absolute Gauge
(%FS)Sealed Gauge
(%FS)Absolute Gauge
(%FS)Sealed Gauge
(%FS)PM620-03A
0 to 0.35
0 to 5
Stainless Steel
0.030
-
0.050
-
0.080
-
PM620-06A
0 to 1.2
0 to 30 inHG
0.020
-
0.036
-
0.070
-
PM620-07A
0 to 2
0 to 30
0.015
-
0.036
-
0.052
-
PM620-08A
0 to 3.5
0 to 50
0.015
-
0.036
-
0.050
-
PM620-10A
0 to 7
0 to 100
0.015
-
0.036
-
0.050
-
PM620-11A
0 to 10
0 to 150
0.015
0.005
0.030
0.020
0.047
0.025
PM620-13A
0 to 20
0 to 300
0.015
0.005
0.030
0.020
0.047
0.025
PM620-14A
0 to 35
0 to 500
0.015
0.005
0.030
0.020
0.047
0.025
PM620-16A
0 to 70
0 to 1,000
0.015
0.005
0.030
0.020
0.047
0.025
PM620-165A
0 to 100
0 to 1,500
0.015
0.005
0.030
0.020
0.046
0.025
PM620-17A
0 to 135
0 to 2,000
0.015
0.005
0.030
0.020
0.046
0.025
PM620-18A
0 to 200
0 to 3,000
0.015
0.005
0.030
0.020
0.046
0.025
PM620-20A
0 to 350
0 to 5,000
0.015
0.005
0.033
0.020
0.049
0.025
PM620-22A
0 to 700
0 to 10,000
0.015
0.005
0.033
0.020
0.049
0.025
PM620-23A
0 to 1000
0 to 10,000
0.015
0.005
0.033
0.020
0.049
0.025
Absolute Ranges (referenced - Vacuum)
Model
Bar
Psi
Compatible
Media typesNLH&R
20 ±2°C (68 ± 4°F)NLH&R
0 ± 50°C (32 ± 122°F)For 24 hrs
for 24 hrs
for 1 Year
Absolute Gauge
(%FS)Sealed Gauge
(%FS)Absolute Gauge
(%FS)Sealed Gauge
(%FS)Absolute Gauge
(%FS)Sealed Gauge
(%FS)PM620T-06A
0 to 1.2
0 to 30 inHG
Stainless Steel
0.020
-
0.036
-
0.070
-
PM620T-07A
0 to 2
0 to 30
0.015
-
0.036
-
0.052
-
PM620T-10A
0 to 7
0 to 100
0.015
-
0.036
-
0.050
-
PM620T-13A
0 to 20
0 to 300
0.015
0.005
0.030
0.020
0.047
0.025
PM620T-14A
0 to 35
0 to 500
0.015
0.005
0.030
0.020
0.047
0.025
PM620T-16A
0 to 70
0 to 1,000
0.015
0.005
0.030
0.020
0.047
0.025
PM620T-165A
0 to 100
0 to 1,500
0.015
0.005
0.030
0.020
0.046
0.025
-
Documents:
Filename Upload date Size DPI 620 Genii Multifunction Calibrator Datasheet 2023.8.10 5.3 MB DPI 612 Pressure Calibrator Datasheet 2019.3.11 4.4 MB
Update Packages:Filename Upload date Size DPI 620 Genii Firmware Update Package 2018.3.25 5.8 MB DPI 612 Firmware Update Package