Additel’s 151 pressure modules have been designed with flexibility and efficiency in mind and can easily be swapped out as needed to meet changing needs and workloads. Higher pressure ADT151 modules cover two separate pressure ranges and come with individual calibrations for each range. This allows for each module to cover a wide range of pressure workloads. Also, each ADT151 is available in (3) different accuracy levels (0.02% FS, 0.01% FS and 0.01% of reading) to meet the demanding needs of our customers. Additel's 151 pressure modules provide users with the flexibility and dependability end users have come to expect.
- Pressure ranges to 15,000 psi (1,035 bar)
- Accuracy of 0.02%FS, 0.01%FS or 0.01%RD
- Fully temperature compensated accuracy
- Two pressure range per module
- Exclusive calibration fixture
- Advanced temperature compensation
- ISO17025 accredited calibration and data included
- Optional calibraiton fixture with software
-
BAROMETRIC MEASUREMENT SPECIFICATIONS
Model[1] Absolute Pressure Range Accuracy ADT151-BP (60~110) kPa ±22 Pa ADT151-BPH (60~110) kPa ±10 Pa
SPECIFICATIONSRange/ModelCompound Gauge pressureMeasurement Type MediaPrecision[3] (%FS)Accuracy[1][4](%FS)Pressure RatingSuggested Controller Compatibility1st range2nd rangeBurst PressureOver PressureGP15K (0~15000) psi (0~1000) bar (0~6000) psi (0~400) bar Sealed gauge G,L 0.007
(0.01)0.01
(0.02)1.3x 1.1x ADT793 GP10K (0~10000) psi (0~700) bar (0~5000) psi (0~350) bar Sealed gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT793 CP6K (-15~6000) psi (-1~400) bar (-15~3000) psi (-1~200) bar Sealed gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT793 CP5K (-15~5000) psi (-1~350) bar (-15~3000) psi (-1~200) bar Sealed gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT793 CP3.6K (-15~3600) psi (-1~250) bar (-15~1500) psi (-1~100) bar Sealed gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT783-3.6K CP3K (-15~3000) psi (-1~200) bar (-15~1500) psi (-1~100) bar Sealed gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT783-3.6K CP2K (-15~2000) psi (-1~140) bar (-15~1000) psi (-1~70) bar Sealed gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT783-3.6K CP1K (-15~1000) psi (-1~70) bar (-15~500) psi (-1~35) bar Gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT783-1K ADT783-3.6K CP500 (-15~500) psi (-1~35) bar (-15~300) psi (-1~20) bar Gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT783-1K ADT783-3.6K CP300 (-15~300) psi (-1~20) bar (-15~150) psi (-1~10) bar Gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT783-1K ADT783-3.6K CP150 (-15~150) psi (-1~10) bar (-15~60) psi (-1~4) bar Gauge G,L 0.007
(0.01)0.01
(0.02)1.3x 1.1x ADT783-1K CP100 (-15~100) psi (-1~7) bar (-15~50) psi (-1~3.5) bar Gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT783-1K CP50 (-15~50) psi (-1~3.5) bar (-15~30) psi (-1~2) bar Gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT783-1K CP35 (-15~35) psi (-1~2.5) bar (-15~15) psi (-1~1) bar Gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT783-1K CP30 (-15~30) psi (-1~2) bar (-15~15) psi (-1~1) bar Gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT783-1K CP15 (-15~15) psi (-1~1) bar (-10~10) psi
(-0.7~0.7) bar[2]Gauge G,L 0.007
(0.01)0.01
(0.02)2x 1.1x ADT783-1K [2]The second range (-10~10)psi accuracy is 0.02%FS, the precision is 0.01%FS.[3] Precision: the error components include linearity, hysteresis, repeatability, resolution, and temperature compensation.
[4] Accuracy: the error components include linearity, hysteresis, repeatability, resolution, reference standard measurement uncertainty, annual drift, temperature compensation, K=2.
Model[3] Differential Pressure Measurement Type Pressure Medium Precision[4] (%FS) Accuracy[1] [5] (%FS) Pressure Rating Suggested Controller Compatibility 1st range 2nd range Burst Pressure Over Pressure DP1K (-400~1000) inH2O
(-1000~2500) mbar(-400~400) inH2O
(-1000~1000) mbarDP G 0.015 0.02 10000 mbar 1.5x ADT783-D DP800 (-400~800) inH2O
(-1000~2000) mbar(-400~400) inH2O
(-1000~1000) mbarDP G 0.015 0.02 10000 mbar 1.5x ADT783-D DP400 (-400~400) inH2O
(-1000~1000) mbar(-200~200) inH2O
(-500~500) mbarDP G 0.015 0.02 4000 mbar 1.5x ADT783-D ADT773 DP300 (-300~300) inH2O
(-700~700) mbar(-150~150) inH2O
(-350~350) mbarDP G 0.015 0.02 4000 mbar 1.5x ADT783-D ADT773 DP200 (-200~200) inH2O
(-500~500) mbar(-100~100) inH2O
(-250~250) mbarDP G 0.015 0.02 4000 mbar 1.5x ADT783-D ADT773 DP150 (-150~150) inH2O
(-350~350) mbar(-100~100) inH2O
(-250~250) mbarDP G 0.015 0.02 4000 mbar 1.5x ADT783-D ADT773 DP100 (-100~100) inH2O
(-250~250) mbar(-50~50) inH2O
(-125~125) mbarDP G 0.015 0.02 1000 mbar 1.5x ADT783-D ADT773 DP50 (-50~50) inH2O
(-125~125) mbar(-30~30) inH2O
(-75~75) mbarDP G 0.015 0.02 1000 mbar 1.5x ADT783-D ADT773 DP30 (-30~30) inH2O
(-75~75) mbar(-20~20) inH2O
(-50~50) mbarDP G 0.015 0.02 1000 mbar 1.5x ADT783-D ADT773 DP20[2] (-20~20) inH2O
(-50~50) mbar(-10~10) inH2O
(-25~25) mbarDP G 0.015 0.02 100 mbar 1.5x ADT783-D ADT773 DP10[2] (-10~10) inH2O
(-25~25) mbar(-5~5) inH2O
(-10~10) mbarDP G 0.015 0.02 100 mbar 1.5x ADT773 DP5[2] (-5~5) inH2O
(-10~10) mbar(-2~2) inH2O
(-5~5) mbarDP G 0.025 0.05 100 mbar 1.5x ADT773 DP2[2] (-2~2) inH2O
(-5~5) mbar(-1~1) inH2O
(-2.5~2.5) mbarDP G 0.025 0.05 100 mbar 1.5x ADT773
[2] Recommended calibration cycle 180 days.
[3] DP300 to DP1000 provides positive range, accuracy and precision specifications continue to apply;
DP10 to DP150 provides a positive range with accuracy and precision specifications of 0.02%FS and 0.015%FS, respectively;
DP2 to DP5 provides a positive range, with accuracy and precision specifications of 0.05%FS and 0.025%FS, respectively.
[4] Precision: the error components include linearity, hysteresis, repeatability, resolution, and temperature compensation.
[5] Accuracy: the error components include linearity, hysteresis, repeatability, resolution, reference standard measurement uncertainty, annual drift,
temperature compensation, K=2.
High-precision Gauge Pressure Module Specifications Model GaugepressurerangeAbsolutePressureRange[1]MeasurementTypeMedia Precision[3][4]Accuracy[2][5]Pressure Rating Suggested Controller Compatibility GP15KM (0~15000) psi(0~1000) bar(15~15015) psi(0~1001) barSealed gaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater1.3x 1.1x ADT793 GP10KM (0~10000) psi(0~700) bar(15~10015) psi(1~701) barSealed gaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater2x1.1xADT793 CP6KM (-15~6000) psi(-1~400) bar(0~6015) psi(0~401) barSealed gaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater2x1.1xADT793 CP5KM (-15~5000) psi(-1~350) bar(0~5015) psi(0~351) barSealed gaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater2x1.1xADT793 CP3.6KM (-15~3600) psi(-1~250) bar(0~3615) psi(0~251) barSealed gaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater2x1.1xADT793ADT783-3.6KCP3KM (-15~3000) psi(-1~200) bar(0~3015) psi(0~201) barSealed gaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater2x1.1xADT793ADT783-3.6KCP2KM (-15~2000) psi(-1~140) bar(0~2015) psi(0~141) barSealed gaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater2x1.1xADT783-3.6K CP1.5KM (-15~1500) psi(-1~100) bar(0~1515) psi(0~101) barGaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater1.3x1.1xADT783-3.6K CP1KM (-15~1000) psi(-1~70) bar(0~1015) psi(0~71) barGaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater2x1.1xADT783-1KADT783-3.6KCP500M (-15~500) psi(-1~35) bar(0~515) psi(0~36) barGaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater2x1.1xADT783-1KADT783-3.6KCP300M (-15~300) psi(-1~20) bar(0~315) psi(0~21) barGaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater2x1.1xADT783-1KADT783-3.6KCP150M (-15~150) psi(-1~10) bar(0~165) psi(0~11) barGaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater1.3x1.1xADT783-1KADT783-3.6KCP100M (-15~100) psi(-1~7) bar(0~115) psi(0~8) barGaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater2x1.1xADT783-1K CP50M (-15~50) psi(-1~3.5) bar(0~65) psi(0~4.5) barGaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater2x1.1xADT783-1K CP35M (-15~35) psi(-1~2.5) bar(0~50) psi(0~3.5) barGaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater2x1.1xADT783-1K CP30M (-15~30) psi(-1~2) bar(0~45) psi(0~3) barGaugeG,L0.008% rdg or 0.004% FSwhichever is greater0.01% rdg or 0.005% FSwhichever is greater2x1.1xADT783-1K 1] Absolute pressure is achieved through the synthesis of the basic gauge pressure module and the optional atmospheric pressure module.[2] The accuracy of the negative pressure part is equal to the accuracy of the positive pressure part, such as the maximum error of -15 psi is equal to the maximum allowable error of 15 psi.[3] FS refers to the positive range, and the accuracy of the negative pressure part is equal to that of the positive pressure part.[4] Precision: the error components include linearity, hysteresis, repeatability, resolution, and temperature compensation.
[5] Accuracy: the error components include linearity, hysteresis, repeatability, resolution, reference standard measurement uncertainty, annual drift, temperature compensation, K=2.GENERAL SPECIFICATIONS
Standard presicionHigh-precision ModelCPXXDPXXGPXXCPXMOperating temperature0.01%FS accuracy: 15 °C to 35 °C ( 59 °F to 95 °F)
Other accuracy: -10 °C to 50 °C (14 °F to 122 °F )Storage temperature-30°C to 70°C (-22°F to 158°F) Relative humidity10% to 95% RH,non-condensing Pressure connection (for external use only) 6 mm (O-ring,3*1.5-NBR70) Enclosure(for external use only)AluminumDimensions (Dia x H)30 mm x 80 mm x 91mm(1.18” x 3.15” x 3.58”) Weight0.5 kg (1.1 lb) Warranty1 Year
-
Documents and Links Additel 151 Digital Pressure Module Datasheet Software and Firmware Name Version Upload Date Size Additel 9054 Module Adjustment Software 1.0.152024-01-22 3 MB